OUTPUT - RS 422 - TTL

OUTPUT CIRCUIT

1 Cable Shield:

  • for RI 30, 36, 58, 59, 76 and RX 70 connected to housing on encoder side

TECHNICAL DATA

code letter R = RS 422 + alarm3 (with UB = DC 5 / 10 - 30 V)
T = RS 422 + Sense4(only with UB= DC 5 V)
Output signals
clockwise rotation (cw)
when looking at the shaft

rectangle pulse sequences
(TTL) for channels A, B, N
and their inverted
Signals , A , B N

switching times
with 1,5 m cable

≤100 ns ≤100 ns

Pulse shape
duty cycle 1:1
Tolerance¹ ±25° electrical
Pulse frequency max. 300 kHz
Output voltage DC 0 - +5 V ²
Output level H ≥ DC 2.5 V / L ≤ DC 0.5 V (TTL level)
Output load max. ±30 mA
short-circuit resistance for UB= DC 5 V: only 1 channel for max. 1 s
(standard RS 422 driver)
with UB= DC 10 - 30 V: all channels fully short-circuit proof
through integrated regulation
reverse polarity protection from UB for UB= DC 5 V: no
with UB= DC 10 - 30 V: yes

1 distance A to B at least 0.45 μs (at 300 kHz)
2 also at UB= DC 10 - 30 V
3 description see outputs - Alarm
4 description see outputs - Sense

CABLE LENGTH

1 related to the original Hengstler cable