code letter | I = push-pull antivalent (with UB= 10 - 30 V) |
Output signals clockwise rotation (cw) when looking at the shaft |
rectangular pulse sequence
|
switching times with 1,5 m cable |
≤ 2 μs ≤ 2 μs |
Pulse shape | |
duty cycle | 1:1 |
Tolerance¹ | ±25° electrical |
Pulse frequency max. | 200 kHz (see cable length) |
Output voltage | 0... + UB |
Output level | H ≥ UB-3 V / L ≤ 2V |
Output load max. | ±30 mA |
short-circuit resistance | all channels fully short circuit proof through integrated regulation |
Reverse polarity protection from UB: | yes |
1 distance A to B at least 0.7 μs (at 200 kHz)
depending on output voltage and frequency (at 25°C)¹:
length | counterclock antivalent |
10 m | DC12 V, 200 kHz |
DC24 V, 200 kHz | |
DC30 V, 200 kHz | |
50 m | DC12 V, 200 kHz |
DC24 V, 50 kHz | |
DC30 V, 25 kHz | |
100 m | DC12 V, 150 kHz |
DC24 V, 25 kHz | |
DC30 V, 12 kHz |
¹related to the original Hengstler cable