OUTPUTS - push-pull

1 Cable Shield:

  • not available for RI 32, 38, 42
  • for RI 41, encoder side not connected to housing
  • for RI 30, 36, 58, 59, 76 and RX 70 connected to housing on encoder side

TECHNICAL DATA

code letter K = push-pull, 10 mA at UB= DC 5 V
or push-pull, 30 mA at UB= DC 10 - 30 V
D = push-pull, 30 mA at UB= DC 5 V
Output signals
clockwise rotation (cw)
when looking at the shaft

Rectangular pulse sequences

(TTL or HTL) for

channels A, B, N

switching times
with 1,5 m cable

≤ 100 ns (DC 5 V, push-pull D)
≤ 250 ns (DC 5 V, push-pull K)
≤ 2 μs (DC 10 - 30 V, push-pull K)

Pulse shape
duty cycle 1:1
Tolerance¹ ±25° electrical
Pulse frequency max. 300 kHz (see cable length)
Output voltage 0... + ...UB
Output level
K K D
push-pull (10 - 30 V) push-pull (5 V) push-pull (5 V)
H ≥ UB-3V H ≥ 2.5 V H ≥ 2.5 V
L ≤ 2 V L≤ 0.5 V L≤ 0.5 V
Output load max.
±30 mA ±10 mA ±30 mA
short-circuit resistance
all channels all channels 1 channel ²
reverse polarity protection from UB
yes yes no

1 distance A to B at least 0.45 μs (at 300 kHz) 2 only 1 channel at a time for max. 1 s

CABLE LENGTH

dependent on output voltage and frequency (at 25 °C)¹:

length push-pull (K) push-pull (D) push-pull (K)
DC 5 V, 10 mA DC 5 V, 30 mA DC 10 - 30 V, 30 mA
10 m 300 kHz 300 kHz DC 12 V, 200 kHz
DC 24 V, 200 kHz
DC 30 V, 200 kHz
50 m 300 kHz DC 12 V, 200 kHz
DC 24 V, 200 kHz
DC 30 V, 100 kHz
100 m 300 kHz DC 12 V, 200 kHz
DC 24 V, 100 kHz
DC 30 V, 50 kHz

¹related to the original Hengstler cable