Function / Application High voltage relay Product line HENGSTLER Relay family 509 Ambient temperature [°C] -25 ... +70 °C Approval - Standards IEC 61810-1 Meets the requirements RoHS
Number of NO contacts 0 ... 1 Number of NC contacts 0 ... 1 Number of CO contacts 0 Dimensions L x W x H [mm] Version with 1 x NO: 72,0 x 42,0 x 43,0 mm Version with 1 x NC: 72,0 x 42,0 x 52,0 mm Housing no special protection Shock resistance [g] 3 g Puls duration (half sinus) 11 ms Vibration resistance [g] 3 g Frequency range [Hz] 10 - 55 Hz Operating time [ms] 40 ms Releasing time [ms] 10 ms Mechanical service life (without load) 3.000.000 switching cycles Connection type Plug connectors 4,8 x 0,8 mm, DIN 46244 Weight [g] 150 g
Drive system DC monostable Nominal coil voltage [V] 12 ... 220 V Coil resistance [Ohm] 78 ... 17,500 Ohm Contact material Max. switching current [A] 10 A Max. switching voltage [V] 5000 V Max. switching capacity [VA] 5000 VA Electrical service life (with nominal load) 100,000 cycles Insulation Reinforced insualtion
Piece per shell or rod [pcs.] 6 pcs. Piece per carton [pcs.] 54 pcs. Country of origin Slovakia Delivery time [weeks] 3 - 4 weeks
Wherever high voltages have to be reliably switched on or - more importantly - off, HENGSTLER H-509 high-voltage relays are to be found. The H-509 relay is available with one NOC or one NCC, each of which is rated for 5 kV switching voltage. H-509 high-voltage relays conform with standard IEC EN 61810-1.
Ordernumber:
H O O - 0 4 509 / 1 1 - ? - 1 0 0 / ? . ?
Ordernumber:
H O O - 0 4 509 / 1 1 - ? - 0 1 0 / 005 . ?