486/487


  • Permanently visible preset
  • Reset manual, electric or automatic
  • Display 3 or 5-digit
  • Plug-and-play in Modular System 400

Interested in our counters, but still have change requests? We are happy to modify it for you so that it fits perfectly.

Learn more

  • Tel.: +49 / 7424 - 89 - 0
We will be pleased to help you.

  • Hengstler GmbH
    Uhlandstr. 49
    78554 Aldingen
  • Tel. +49 / 7424 - 89 -0
  • Support request
Product Family486/487
FunctionPreset counter
TechnologyElectromechanical
Digits
  • 3-digit
  • 5-digit
Display
  • 3-digit
  • 5-digit
Preset1 preset
Digit Height [mm]4 mm (0.2 in)
Voltage
  • 12 - 220 VDC
  • 24 - 230 VAC
Reset
  • manual reset
  • electrical reset
  • key reset
Signal Timesfrom when preset has been reached until reset
Duty Cycle at 25 °C
  • DC: counter 100%, reset magent: 20%, max. 2 min.
  • AC: counter 100 %, reset magnet: 10 %, max. 1 min
Duty Cycle at 50 °Ccounter 50 % max. run time 10 min
Pulse Duty Factor Reset Impulse
  • DC: 1:5
  • AC: 1:10
Power Consumption
  • DC: counter 2.5 W, reset magnet 12 W
  • AC: counter 2.75 VA, reset magnet 16 VA
Pulse Length min.
  • DC: counter 20 ms, reset magnet 200 ms
  • AC: counter 50 ms, reset magnet 200 ms
Residual Ripple [%]DC: 48 %
Supply Voltage
  • 12, 24, 48, 60, 110, 220 VDC
  • 24, 42, 48, 100, 115, 200, 230 VAC
Contact Typefloating changeover contact
Switching Voltagemax. 220 V AC
Switching Current
  • max. 20 VA / 1 A
  • non-inductive
Count Frequency [Hz]
  • DC: counter 25 Hz, reset magnet 1 per s
  • AC: counter 10 Hz, reset magnet 1 per 2 s
Count Inputadding
Pulse Duty Factor Count Impulse
  • DC: counter 1:1
  • reset magnet: 1:5
  • AC: counter 1:1
  • reset magnet: 1:10
Reset Frequency
  • DC: max. 1 per s
  • AC: max. 1 per 2 s
Electrical ConnectionAMP connector plug 0.8 x 2.8 mm (0.3 x 1.1 in) (via connection box)
Maintenance-Free operation
  • counter 2 x 10? pulses
  • reset magnet 1.5 x 10? pulses
IP Protection ClassIP 30
Operating Temperature [°C]–- 10 ...… + 50 °C (+ 14 ... 122 °F)
Storage Temperature [°C]–- 40 ...… + 85 °C (+ 14 ... 122 °F)
Degree of Protection
  • front IP 30
  • connections IP 00
  • for a higher protection class, we recommend a protective case with transparent cover (see Accessories)
General DesignEN 61 010-1 / IEC 61010-1
ApprovalsUL: E 349078
Protection ClassII, EN 61010-1 / IEC 61010-1
Contamination Level
  • V 2
  • EN 50178
Size [mm]50x50x76
Mounting OptionsModular system 400
MountingCan be combined in modular system 400
Reset
  • manual reset
  • electrical reset
  • key reset
Weight [g]approx. 145 g (3.2 oz)
Mounting Positionhorizontal rolling axis

The user-friendly Type 486-487 is an electronic adding preset counter. It is available with a 3 or 5-digit display and the preset remains visible at al times. Depending on the version, Type 486-487 offers manual, electric or even optional automatic reset. It is a plug-and-play device and can easily be combined with other counters in the modular 400 series.