tico 732 Multifunctional counter

    Interested in our counters, but still have change requests? We are happy to modify it for you so that it fits perfectly.

    Learn more

    • Tel.: +49 / 7424 - 89 - 0
    We will be pleased to help you.

    • Hengstler GmbH
      Uhlandstr. 49
      78554 Aldingen
    • Tel. +49 / 7424 - 89 -0
    • Support request
    Product Familytico 732
    FunctionMultifunctional counter
    TechnologyElectronic
    Digits6-digit
    Display
    • 6-digit
    • count reading / preset
    • leading zero suppression
    • decimal point
    Preset
    • 1 preset
    • 2 presets
    • without presets
    Digit Height [mm]
    • LCD 9 mm (0.4 in)
    • LED 7.6 mm (0.3 in)
    Display Variant
    • LCD
    • LED
    Voltage
    • 12-24 VDC
    • 24-230 VAC
    Reset
    • manual reset
    • electrical reset
    Signal Times0.02 s to 1 s or bistable
    Current Consumption [mA]
    • 12-24 VDC, LCD: <100 mA
    • 12-24 VDC, LED: 150 mA
    • 24 VAC: <250 mA
    • 100 VAC: < 60 mA
    • 115 VAC: <50 mA
    • 230 VAC: <25 mA each, incl. power to sensor
    Input Resistanceapprox. 10 k? (static)
    Pulse Length min.
    • 17 ms (30 Hz)
    • 100 ?s (5 kHz)
    Supply Voltage
    • 12-24 VDC
    • 24, 100, 115, 230 VAC
    Count Frequency [Hz]max. 5 kHz (2,5 kHz using 2 channels)
    Sensor Supply
    • 12 - 30 VDC
    • max. 50 mA
    Storage of ValuesNVM> 10 years
    Electrical Connectionscrew terminals
    Amplitude Threshold
    • < 2 V and> 8 V or < 2 V and
    • > 3.8 V at TTL levels
    • max. 40 VDC
    Active Edgeprogrammable, positive with PNP input, negative with NPN input
    Pulse Shapeany square wave (1:1 for max. frequency)
    Prescalerfrom 0.001 to 999.999 programmable
    Relay (Preset 1 and 2)
    • Varistor max. 250 VAC / 30 VDC
    • min. 5 V AC/DC
    • max. 5A
    • min. 10 mA
    • delay < 10 ms
    Transistor output (Preset 1 + 2)
    • DC supply: PNP
    • active high
    • VDC-2V (supply voltage-2 V)
    • max. 30 mA
    • transformer version:PNP
    • active high
    • 12-30 VDC
    • max. 30 mA
    Measuring Principle (tachometer)period measurement (1/tau)
    Display Range1/min or 1/sec
    min. Frequency0.125 Hz = 8 sec
    Limit Values2 alarms with programmable start suppression
    Time Base (Tachometer)
    • programmable, sec
    • min
    • h or hh.mm.ss
    Measuring Principle (timer)pulse width or period duration measurement (start-stop)
    Function Time Countersingle pulse measurement (short meter) or cumulative measurement (hour meter)
    Resolutionprogrammable 1, 0.1, 0.01, 0.001
    IP Protection ClassIP 65
    Operating Temperature [°C]0 ... + 50 °C (+ 32 ... 122 °F)
    Storage Temperature [°C]–- 20 ...… + 70 °C (+ 14 ... 122 °F)
    Degree of Protection
    • front IP 65
    • connections IP 20
    Cable Length< 30 m
    General DesignEN 61 010-1 / IEC 61010-1
    ApprovalsUL + CUL E 96 337
    Vibration Resistance10 m/s² (33 ft/s²) (10 ... 150 Hz) acc. IEC 68-T2-6
    Shock Resistance100 m/s² (328 ft/s²) (18 ms) acc. IEC 68-T2-27
    Protection ClassII, EN 61010-1 / IEC 61010-1
    Contamination Level
    • V 2
    • EN 50178
    Size [mm]48x48x108
    Mounting OptionsClamping frame
    Mountingwith clamping frame
    Reset
    • manual reset using keypad
    • external reset
    • static or dynamically programmable
    • pulse duration> 5 ms
    • automatic reset after main preset has been reached (programmable)
    TypeMultifunctional counter